| Model | S70 | S70G | S80 | S80G | S90 | S90G | S100 | S100G |
|---|
External demensions W-H-D (mm) | 340 - 380 - 490 | 380 - 380 - 490 | 380 - 450 - 540 | 420 - 450 - 540 | 490 - 510 - 600 | 530 - 510 - 600 | 655 - 770 - 910 | 695 - 770 - 910 |
|---|
Chamber demensions W-H-D (mm) | 120 - 90 - 220 | 170 - 150 - 260 | 240 - 210 - 295 | 350 - 300 - 500 |
|---|
| Chamber capacity | 2.4L | 6.6L | 14.9L | 52.5L |
|---|
| Weight | approx. 20.5kg | approx. 21.5kg | approx. 26.5kg | approx. 27.5kg | approx. 39.0kg | approx. 40.0kg | approx. 124.0kg | approx. 125.0kg |
|---|
| Power requirement | AC100V 50/60Hz | AC200V 50/60Hz |
|---|
| Power consumption | 1.4kW | 3.0kW | 4.0kW | 8.0kW |
|---|
Ordinary/Max. temp. | 1050ºC / 1150ºC | 1000ºC/1100ºC |
|---|
| Temp. range | 100ºC - 1150ºC | 100ºC - 1100ºC |
|---|
Temp. control unit of measure | 0.5ºC |
|---|
| Heat distribution range | ±3ºC at 1000ºC |
|---|
| Muffle wall material | Ceramic fiber |
|---|
| Thermo-couple | JIS - K type |
|---|
| Heating element material | Alloys of Fe, Cr and Al | Kanthal heating element |
|---|
| Diameter of gas outlet | φ23 |
|---|
| Safety devices | Cooling fan , Over-current breaker, over-heat temp. set device, rear cover sensor, Micro-computer malfunction detector ( computer failure, heater breakdown, abnormal heat-up, memory failure ) |
|---|
Max. temp. up time | approx.45min. up to 1050ºC/ approx. 60 min. up to 1150ºC | approx.15min. up to 1050ºC/ approx. 18 min. up to 1150ºC | approx.22min. up to 1050ºC/ approx. 30 min. up to 1150ºC | approx.33min. up to 1000ºC/ approx. 42 min. up to 1100ºC |
|---|
| Gas injection unit | Optional | built-in (Nitrogen 2L/min) | Optional | built-in (Nitrogen 2L/min) | Optional | built-in (Nitrogen 5L/min) | Optional | built-in (Nitrogen 20L/min) |
|---|
| Control method | time-sharing P.I.D. control ( with auto tuner ), P.I.D. constant ... one kind per each pattern |
|---|
| Program storages | 9 patterns ( one kind of, start reservation time, temp. up-and-down time and hold time per pattern avairable ) |
|---|
| Pattern links | optional 4 patterns in a link |
|---|
| Program | Preset time, Temp. up-and-down time, Set temp., Soak stop, Gas flow command |
|---|
| Preset timer/ Temp. rise time/ Hold time | 0-99 hours and 59 min. |
|---|
| External terminals | Thermo-couple terminal for recorder, AC power output terminal for gas injection, Terminal for deodorizer connection |
|---|
| Chamber atmosphre | Air | Nitrogen, oxygen, Argon, etc. | Air | Nitrogen, oxygen, Argon, etc. | Air | Nitrogen, oxygen, Argon, etc. | Air | Nitrogen, oxygen, Argon, etc. |
|---|
| Accessories | Ceramic plate, Blunk plug for exhaust outlet, AC power code ( attached in the 70 series ), Gas injection unit ( G type only ), Instruction manual, User's card |
|---|
| Optionals |
|---|
| Applied Model | S70 | S70G | S80 | S80G | S90 | S90G | S100 | S100G |
|---|
| Deodorizer | ES7S / ES71S | ES72S |
|---|
| Exhaust Fumes Ventilator | VF71S | VF72S |
|---|
| Gas injection unit | KDG-70 | Built-in | KDG-80 | Built-in | KDG-90 | Built-in | KDG-100 | Built-in |
|---|
| Carrying wagon | KDW-100 / KDW-200 | KDW-200 |
|---|